Centrifugal Pump · 2026-03-12Irrigation and floodproof pump stations have specific needs: large flow, low pressure column (usually a few meters) and seasonal work, sometimes running only a few hundred hours per year.
resistance to flooding.
The flow of rainwater to be consumed can be estimated by a logical method: Q = 0.278·C·i·A (m3/s), with C as the flow factor, i as the calculated rain intensity (mm/hour) and A as the basin area (km2).
The pressure changes with the water level.
The river level or outer tide changes so the static pressure column changes over time. It is necessary to check the working point at both the lowest and highest ink; the pump should not fall into the flow area too large or too small.
Start and start.
If the pump height is higher than the suction water level, a vacuum bearing system is needed; a pump placed lower than the water level (sink pump or steady axle pump) avoids this step. Starting multiple pumps at the same time must calculate the power grid’s starting current.
Prepare for the rainy season.
- Turn the axle hand, check the bearings and oil before the season.
- Running without loading and having loaded several times before the peak.
- Check the one-way valve, door valve and backup power supply.
Need help choosing equipment?
Contact usRelated articles
City water level and high-pressure station
A city water station runs thousands of hours a year, so electricity accounts for most of its life cycle costs; the purchase price of a pump is…
The central air conditioning system.
In the central air conditioning system, the cold water pump, the heating water pump and the hot water circulation pump run almost continuously…
Chemical pump for corrosive environment.
Chemical pumps are not only corrosion-resistant but must also be kept closed: acid, alkaline or solvent leakage is dangerous to humans and the…
Power plant: water supply boiler and circulating water
Thermal power plants use many groups of centrifugal pumps with very different characteristics: boiler water pump, water pump, cooling water…
Water treatment and drainage.
The waste water pump station works with liquid containing solid materials, fabric, paper and oil, different from the clean water pump. Two popular…
Oil and petroleum chemicals: process pumping according to API 610
API 610 (equivalent to ISO 13709) is the centrifugal pump standard for petroleum gas, petrochemicals and gas. Compared to conventional industrial…
Pump for the fire system.
A fire-fighting pump is a safe device: it can remain silent for years but must run properly when there is an accident.
Exercise and Kim.
Mines need two main groups of pumps: pipe drainage pump and mining hole, and water supply pump, circulating for mineral collection. Mining water…